PRODUCTS
IMAGENEX MODEL 831LDIGITAL PIPE PROFILING SONAR
APPLICATIONS:
FEATURES:
HARDWARE SPECIFICATIONS:
FREQUENCY
2.25 MHz
TRANSDUCER
Profiling type, fluid compensated
TRANSDUCER BEAM WIDTH
1.4o conical
RANGE RESOLUTION
1/250 of full scale range (e.g. 1mm at 250 mm)
MIN. DETECTABLE RANGE
50 mm (~2")
MAX. OPERATING DEPTH
1000 m
MAX. CABLE LENGTH
1000 m on typical twisted shielded pair(RS-485)
INTERFACE
Standard: 10 Mbps Ethernet (10 BASE-T) using TCP/IPBit rate may vary if an Ethernet extender is in use.
CONNECTOR
End mounted, eight conductor, wet mateable(Subconn MCBH-8M-SS)
POWER SUPPLY
20 - 36 VDC at less than 5 Watts
DIMENSIONS(for both depth ratings)
61 mm (2.4") diameter x 343 mm (13.5") overall length
WEIGHT: In Air
In Water
1.2 kg (2.6 lbs)
0.4 kg (0.8 lb)
MATERIALS
6061-T6 Aluminum & Polyurethane
FINISH
Hard Anodize
SOFTWARE SPECIFICATIONS:
PipeSonarL.exe
WINDOWS OPERATING SYSTEM
Windows 98, Me, NT, 2000, XP, Vista
MODES
Polar
RANGE SCALES
0.125 m, 0.25 m, 0.5 m, 0.75 m, 1 m, 2 m, 3 m, 4 m, 5 m, 6 m
STEP SIZE
0.9o
GRID TYPES
Polar and rectangular
FILE FORMAT
(filename).31L
RECOMMENDED MINIMUM COMPUTER REQUIREMENTS:
2 GHz Pentium 4256 MB RAM20 GB Hard Disk1024 x 768 screen resolution
ORDERING INFORMATION:
1000 m UNIT
Standard
831L-000-200
IP Address*
Option
-020
*Note: Standard IP Address is 192.168.0.5 A different IP Address may be specified upon ordering.
To download a printable version of this spec sheet click hereYou need Adobe Acrobat Reader to open this file
Specifications subject to change without notice.
Phone: (604) 944-8248Fax: (604) 944-8249e-mail: imagenex@shaw.ca